Selection conditions
Set the timing before the current. The pulse shape is defined by 5–40ms forward and 0.5–5.0ms reverse time with a 0–100% duty cycle, so confirm the recipe first. Then size the peak current within 0–50kA.
Corresponding parameters
Current spans 0–50kA. Duty runs from 0% to 100%, forward time from 5 to 40ms, and reverse time from 0.5 to 5.0ms. Those four figures define the pulse window available to the process engineer.
| Parameter | Value |
|---|---|
| Output current | 0–50kA |
| Duty cycle | 0–100% |
| Forward time | 5–40ms |
| Reverse time | 0.5–5.0ms |
Process fit
PCB deep-hole plating needs a much faster ≤50μs changeover, which the PCB electroplating power supply handles. This unit suits broader pulse recipes where millisecond timing is enough. Board thickness stays a process input.
Lead time and warranty
Standard and custom builds ship in 15–20 days with a one-year warranty. Pulse timing is a process recipe, not a fixed product setting.