Process pain points
Deep holes starve of metal when current cannot reach the barrel wall. Straight DC throws most of its metal at the surface. A reverse pulse pulls metal back from the high-current edge and drives it into the hole, but only if the changeover is fast.
What the power supply must deliver
Forward peaks span +40–800A and reverse peaks −120–2400A. Changeover takes ≤50μs and ripple stays below 1%. The unit offers panel, meter-box, and RS485 control so setpoints can be logged with the board recipe.
| Parameter | Value |
|---|---|
| Forward pulse peak | +40–800A |
| Reverse pulse peak | −120–2400A |
| Switching time | ≤50μs |
| Ripple | below 1% |
| Control | panel / meter box / RS485 |
Matching model
Board thickness, line width, and plating area set the recipe; they are process inputs, not fixed page values. When a line needs broader pulse timing, the pulse power supply covers 0–50kA with adjustable forward and reverse times.
Verification
Acceptance records the ≤50μs switching time and ripple below 1% under load. Standard and custom builds ship in 15–20 days with a one-year warranty. Board-specific current is set by the process engineer.