Selection conditions
Start with current. This rectifier covers 500–8000A, so a line outside that band needs a different series. Fix DC 0–12V next, then settle cooling. Air-cooled and water-cooled versions share the same electrical envelope.
If your line runs continuous high current, air cooling stops being practical. Cooling changes the installation, not the current rating.
Corresponding parameters
Read the figures as a selection envelope, not a promise for every model. Efficiency tops out at 96%; it is not a continuous full-load rating.
| Parameter | Value |
|---|---|
| Output current | 500–8000A |
| Output voltage | DC 0–12V |
| Rated power | 6–96kW |
| Voltage / current regulation | ≤1% |
| Power factor | ≥0.94 |
| Efficiency | up to 96% |
| Cooling | air or water |
The acceptance test uses ≥0.94 power factor and ≤1% regulation as its two reference points.
Process fit
The 500–8000A platform covers PCB and hardware plating. For chrome work, ripple, not nameplate current, decides the finish; the low-ripple chrome series holds ripple at ≤3%. A line needing reverse pulses moves to the PCB series.
Lead time and warranty
Standard and custom models ship in 15–20 days. The warranty runs one year. Water-cooled installations need site water quality, flow, pressure, and temperature confirmed before order; those values stay out of the product sheet.