Selection conditions
Compare the bottom heater voltage against the 0–55V window. If the hot zone needs more than 40V, this is the model. Then check the furnace's mains condition against the stated 380V ±10% input range.
Corresponding parameters
Rated output is 1400A at 55V with a 0–77kVA envelope. DC output from zero to rated voltage holds ±1% precision. AC input is 380V ±10% at 50Hz ±3Hz, which matches typical plant supply.
| Parameter | Value |
|---|---|
| Rated output | 1400A / 55V |
| Power range | 0–77kVA |
| DC precision | ±1% |
| AC input | 380V ±10%, 50Hz ±3Hz |
Process fit
Lower-voltage furnaces use the 1350A/40V bottom heating power supply. Where main and bottom heaters share one rack, the dual-circuit build combines 3000A/55V and 1350A/40V. All three serve crystal growth.
Lead time and warranty
Standard and custom builds ship in 15–20 days with a one-year warranty. Hot-zone voltage is a furnace input, not a fixed process value.