Process pain points
The bottom heater sets part of the thermal gradient in a crystal furnace, so its supply must track the main heater without drifting. A mains variation of ±10% is normal in a plant, and the unit has to absorb that without moving the setpoint.
What the power supply must deliver
Output is 1350A at 40V within a 0–54kVA envelope. IGBT pulse-width modulation shapes the DC output, held at ±1% precision from zero to rated voltage. Input is AC 380V ±10% at 50Hz ±3Hz.
| Parameter | Value |
|---|---|
| Rated output | 1350A / 40V |
| Power range | 0–54kVA |
| Control method | IGBT pulse-width modulation |
| AC input | 380V ±10%, 50Hz ±3Hz |
| DC precision | ±1% |
Matching model
A 1400A/55V variant covers furnaces needing higher voltage. Dual-circuit builds pair a bottom heater with a main heater when the process needs both on one control system. Both belong to the crystal heating cluster.
Verification