Selection conditions
Check the hot-zone voltage first. This unit runs at 0–12V, lower than the 0–55V platform, so it suits a different heater design. Then review the stepping requirement: 0.004% step precision is the reason to choose this model.
Corresponding parameters
Output runs 0–12V continuously adjustable at ±0.5% across a 0–144kVA range. Stability is 0.01% and step precision 0.004%. Those two fine figures separate this unit from the broader 1000–10000A sapphire platform.
| Parameter | Value |
|---|---|
| Output voltage | 0–12V continuously adjustable |
| Voltage precision | ±0.5% |
| Power range | 0–144kVA |
| Stability | 0.01% |
| Step precision | 0.004% |
Process fit
Furnaces that need many small voltage steps use this 50Hz unit. Larger hot zones use the 1000–10000A sapphire heating power supply at 0–55V. Both belong to the same sapphire cluster but serve different heater designs.
Lead time and warranty
Standard and custom builds ship in 15–20 days with a one-year warranty. Heater design is a furnace input and is not fixed here.