Selection conditions
Set the ripple ceiling before the current. Film formation reacts to ripple, so ≤3% belongs in the technical condition. Then confirm the forming voltage and current for the foil grade, and check the plant power factor requirement.
Corresponding parameters
Current and voltage stability sit at ≤1%. Ripple is ≤3%, efficiency reaches up to 96%, and power factor is ≥0.9. Those figures sit together because forming quality and utility cost are both part of the selection.
| Parameter | Value |
|---|---|
| Current / voltage stability | ≤1% |
| Ripple | ≤3% |
| Efficiency | up to 96% |
| Power factor | ≥0.9 |
Process fit
Copper foil generation uses the copper foil electrolysis power supply with 5% ripple and water cooling. Forming needs the tighter ≤3% figure because the dielectric film reacts to the waveform. The two stages are separate lines.
Lead time and warranty
Standard and custom builds ship in 15–20 days with a one-year warranty. Forming voltage and foil grade are process inputs and are not fixed on this page.