Process pain points
Some workshops have no cooling water circuit, and a water-cooled rectifier cannot be installed. Forced air removes that dependency, but the unit then has to tolerate the plant's ambient temperature and humidity.
What the power supply must deliver
Regulation sits at ≤1% for voltage and current. The operating window is −10 to 45°C with relative humidity of 30%–85%. Those limits describe the environment the forced-air rectifier is built to work in.
| Parameter | Value |
|---|---|
| Voltage / current regulation | ≤1% |
| Operating temperature | −10 to 45°C |
| Relative humidity | 30%–85% |
| Cooling | forced air |
Matching model
The standard SCR rectifier shares the ≤1% regulation and temperature range on AC 380V ±10%. The SCR controller handles phase control at 0–120kVA. Plants with water and higher current look at the high frequency switching platform.
Verification
Acceptance checks ≤1% regulation within the stated temperature and humidity window. Standard and custom builds ship in 15–20 days with a one-year warranty.